HydroRed-ZS Filter

Y TYPE SELF CLEANING STRAINER
Self Cleaning Strainer

Self-cleaning Y strainer HydroRed-ZS is often used in the pipeline transportation process. It can filter and eliminate impurities in the pipeline. Therefore, it can effectively protect the normal work and operation of equipment, pumps, valves, and instruments on the pipeline.

  • HydroRed-ZS Material: stainless steel, carbon steel.  
  • OD: DN15-DN500.  
  • Single unit processing capacity: 25 – 650 cubic meters per hour.  
  • Maximum working pressure: 0.1-1.5 Mpa.
  • Pressure loss during filter cleaning: ≤0.015 Mpa.
  • Maximum working water temperature: 120 degrees.  
  • Filtration precision range: 100-1500 microns.  
  • Amount of water required for self-cleaning: less than 1.0%。  
  • Self-cleaning time: 10-200 seconds.
  • Self-cleaning control methods: pressure difference, time, and manual.  
  • Electrical control method: AC three-phase, 380V/50Hz.  
  • Control interface: digital display, knob, switch.
  • Sealing ring: EPDM rubber, PTFE, etc.
  • Drain valve: cast iron, copper, stainless steel.  
  • Installation location: Pressure reducing valve, pressure relief valve, fixed water level valve, or the inlet end of other equipment.
  • Special materials such as nickel and titanium alloys can be selected according to customer needs. Please consult us for specific conditions.

How to choose the right self-cleaning Y strainer?

Inlet and outlet: In principle, the inlet and outlet diameter of the self-cleaning strainer should not be smaller than the inlet diameter of the matching pump. Generally speaking, it is the same diameter as the inlet pipe.
Nominal pressure: Determine the pressure rating of the filter according to the higher pressure that may occur in the filter line.
Filtration accuracy: Refers to the particle size of impurities to be intercepted and the process requirements of the media process.
Material: The material of self-cleaning strainer is generally the same as the material of the connected process pipeline. Consider choosing a filter made of cast iron, carbon steel, low alloy steel, or stainless steel.
Calculation of resistance loss: For water filters, under the generally calculated rated flow rate, the pressure loss is 0.52 – 1.2kp.

HydroRed-ZS drawing
HydroRed-ZS drawing

Technical Parameters

ModelODFilter flowFilter areaValveODMaxflowWeightODABB1CC1GHL
inchT/hCm2mmkgkgmmmmmmmmmmmmmmmmmm
HydroRed-ZS015025300025609027365083213005528502252331500
HydroRed-ZS026530300025609527365083213005528502252331500
HydroRed-ZS0380603000256010627365083213005528502252331500
HydroRed-ZS04100803000256011027365083213005528502252331500
HydroRed-ZS051251203000256011827365083213005528502252331500
HydroRed-ZS061501605900401501653258001318215092015002953102800
HydroRed-ZS072003005900401501853258001318215092015002953102800
HydroRed-ZS0825045095005020028542612001480230094215003254003000
HydroRed-ZS0930065095005020032042612001480230094215003254003000

The above parameters are for reference only. If you need customization of special material HydroRed-ZS, please send us an email. Our technical staff will give you the best solution within 48 hours.

Installation and Use

  • When installing and using, please pay attention to the protection of the control box, sensors, and transmission parts to prevent damage.
  • Connect the pipes according to the direction of the arrow on the HydroRed-ZS filter body. Make the water flow direction consistent with the arrow square on the body.
  • This series of self-cleaning strainers is available in two installation styles: vertical or horizontal.
  • No matter which installation method is chosen, the outlet direction of the automatic drain valve should be horizontal or downward. To ensure more complete sewage discharge.                                                                                
  • The conventional installation location is in front of the water-using equipment and as close as possible to the water-using equipment.  
  • The connection methods of the drain valve are divided into flange and thread. The sewage pipe should not be too long, no more than 10 meters.  
  • When the pressure difference between the inlet and outlet pressure gauges reaches 0.5kg, it will automatically enter the cleaning process. Then open the drain valve to drain the sewage until the pressure difference is normal.
  • In the self-cleaning process, there is no need to disassemble the pipe body and it does not affect the normal operation of the equipment. 
  • Flushing and draining can work at full flow. It not only maintains a high flow rate of the system but also has a very low-pressure drop. This eliminates surface stains caused by low flow rates.
  • The inner scraper uses inorganic materials. Good elasticity, high strength, excellent corrosion resistance, and aging performance.